Manual GSE-Humidifier-Dehumidifier controller
The humidity controller can handle a dehumidifier or a
humidifier - fogger machine. To reduce humidity you need to
connect a dehumidifier to the socket. Choose the desired humidity
on your left knob and choose the function on the right knob, for
dehumidifying use the orange part from -1% to -10% hysteresis.
For example, set the desired humidity to 60% and set the
dehumidification hysteresis to -1%. Now the controller starts your
dehumidifier above 60%, and stops -1% at 59%. If you set the
humidity hysteresis to -10%, the controller starts the dehumidifier
above 60% and stops -10% at 50%.
To increase the humidity you have to connect a humidifier
fogger machine. Make sure the fogger don't blow aerosol directly
into the humidity sensor! Choose the desired humidity on your left
knob and choose the function on the right knob, for humidifying
use the blue part from 1% to 10% hysteresis. For example, set the
desired humidity to 60%, and set the humidification hysteresis to
1%. Now the controller starts your humidifier below 60% and stops
+1% at 61%. If you set the humidity hysteresis to 10%, the
controller starts the humidifier below 60%, and stops +10% at
70%.
The controller must be connected to a domestic socket with a
13A fuse. If there is a fault in the appliance check the fuse first of
all. Always disconnect the power before opening the plug. There
are life threatening voltages in the appliance. 230V DANGER TO
LIFE!!!