The power supply model 121 can works at 230 or 115Vac.
If you want to use the power supply for 115Vac you have to proceed as follows:
Input voltage must be disconnected from the supply before to open the device.
Remove carefully the rear cover of the power supply.
Remove the bridge marked as "230" (Figure 3).
Weld the bridges marked as "115" (Figure 4).
Change the 100mA fuse for a 200mA fuse.
Disconnect the input voltage.
Remove the front cover from the power supply.
Press down gently on the cover of the fuse
holder, and turn counter-clockwise (Figure 5).
Pull out the cover and fuse, replace fuse with a
new one.
Re-install fuse and cover as an assembly, press
down gently and turn clockwise.
Replace the front cover on the power supply.
INPUT VOLTAGE SELECTION

FUSE REPLACEMENT