Operating temperature range:
Storage temperature range:
Relative humidity:
Input power supply:
Voltage output:
Working power:
Max. power(Peak):
Fuse:
This power supply can power a single DAT transmitter with six 350Ω load cells.
The following symbols are used in this manual to draw the user's attention:
Danger! Risk of electrical shock.
Attention! This procedure is to be performed by qualified service personnel.
This manual contains important information concerning the installation and opening procedures for this
device.
The power supply unit should not be installed or operated until the installer has reviewed the
information provided in this manual.
Apply power to the unit within the specified range as provided in the "Technical Data" section of
this manual.
The user should assure that the installation metes the local electrical codes and regulations.
In the event of malfunction, please contact the nearest distributor for assistance. Any attempt to
modify or repair the unit will void the manufacturer's warranty.
WARNINGS
WIRING (Figure 1)

TECHNICAL DATA

WARNINGS
INSTALLATION
The following procedures require work inside the power supply enclosure.
These procedures are to be performed by qualified service personnel.
Remove the power prior to making any wiring connections.
The AC input voltage must be connected to terminal block "MA".
The DC output voltage is available on terminal block "MB".
The LED is illuminated when the power supply is "ON" (See figure2).
-10 a +50 °C (14 a 122°F)
-20 a +70 °C ( -4 a 158°F)
85% non-condensing
230 Vac / 115 Vac (50/60Hz)
24 Vcc unregulated
10 W
15 W
100 mA (230 Vac) / 200mA (115 Vac)