1.
DESCRIPTION
1.1
Envisaged use and fi eld of application
NK CONTROL SYSTEM is used for electronic control of NK
series sliding door automations.
The fi eld of application is limited to automatic doors with
one or two horizontal sliding wings used in civil, public or
industrial applications, in dry areas, in covered entrance
areas and foot traffi c passageways.
!
Warning
Do not use the product for purposes other than those
envisaged by the manufacturer or for any improper use.
Do not tamper with or modify the product.
The product must only be installed using APRIMATIC
material.
!
Warning
Keep children away from the operating range of the device
at all times.
Keep control devices in a safe place to prevent use by
children or unauthorised people.
1.2
Technical features and data
See Tab.1.
Before installing the product, check that the temperature
range marked on the drive is suitable for the location.
BASE SYSTEM COMPONENTS
See fi g.1.
CONTROL NK control unit
1
POWER SUPPLY unit
2
EMERGENCY BATTERY unit
3
24 VAC GEARMOTOR
4
ACCESSORY DEVICES
See fig.2 for the ACCESSORY devices which can be
installed.
WARNING! Correct functioning of the automation requires
the installation of the control device: Key selector.
IMPORTANT! Also consult the specific instructions
supplied with each accessory.
CONTROL NK
- 15 -
tab. 1 -
:
POWER SUPPLY VOLTAGE
:
EXTERNAL DEVICE VOLTAGE
20 A rapid fuse for card power
CARD PROTECTIONS
supply - short-circuit electronic
two 3.15/[6.3] A delayed fuses on
POWER SUPPLY UNIT
PROTECTIONS
A C C E S S O RY P O W E R
SUPPLY PROTECTION
:
TEMPERATURE RANGE
:
two 12 V - 2 Ah batteries
EMERGENCY BATTERIES
-
BATTERY
CHARGER
:
AUTOMATIC DIAGNOSTICS
:
SERIAL COMMUNICATION PORT
11 - 75 cm/s
O P E N I N G
S P E E D
ADJUSTMENT
C L O S I N G
S P E E D
ADJUSTMENT
11 - 50 cm/s
11 - 75 cm/s
:
APPROACH SPEED
SELF
:
INVERSION SENSITIVITY
0 - 45 sec. (continuously adjustable)
DOOR OPENING TIME
PARAMETERS ADJUSTABLE BY TRIMMER
electric lock activation delay, opening and closing appro-
aching speed, thrust force (torque adjustment using current
control), opened door pause time, opening speed, partial
wing opening percentage
PARAMETERS ADJUSTABLE BY DIP SWITCH
fixed or adaptive partial opening,
enabling,
master/slave mode enabling,
(as percentage of opening speed), photocell contact type,
emergency operation (opening or closing),
enabling for "exit only" operation mode, settings during power
failure: continuation or application of the last operation (using
emergency batteries), settings if emergency batteries reach
critical threshold during power failure: >ast operation (opening
or closing), >electric lock maintained, >electric lock OFF.
fi g. 1 -
Base components
3
2
1
CONTROL UNIT
Technical features and data
230 V ~ (+/- 10 % )
[115V
]
ON DEMAND
24 V
threshold at 45 A
mains
PTC 1 A resettable fuse
- 20 ÷ + 70 °C
- maintenance-free -
built into CONTROL NK card
buzzer signals
RS 485
22 - 150 cm/s
(1 wing)
(2 wings)
DIP SWITCH al 50%
22 - 100 cm/s
(1 wing)
(2 wings)
DIP SWITCH al 100%
22 - 150 cm/s
(1 wing)
(2 wings)
-
(approx. 6 cm/s)
LEARNED
adjustable
:
:
break-in response
closing speed
electric lock
4