Set Point Ec - Prosystem AQUA PH&EC PLUS Manual De Usuario

Tabla de contenido

5.1 SET POINT EC

A. Password
✓ Position "OFF" button ON/OFF. In Display will appear "SBY".
✓ Press "CAL" 5 second, for programming menu.
✓ Password. We can introduce password, by defect is 000.
Change password, press "CAL" y flashing Ec value in Display. Press "SET" for change value
and press again "CAL" to confirm value.
Press "SET" continue programming.
1. Set point Ec.
Press "CAL" Ec value flash in Display , press "SET" for change Ec value and press again "CAL"
to confirm.
Press "SET" continue step 2.
2. Temperature.
Value for defect "025", don't change.
Press "SET" continue step 3.
3. Alarm Dosing time.
We can stablish alarm dosing time from 0 second until 999 second.
If in the stablish time, the set point of Ec isn't control, the controller will send out alarm
OFF1 – It will appear in display if the Ec value isn't control in the stablish time.
The controller will continue dosing
OFF2 – It will appear in display if the Ec value isn't control in double of stablish time.
The controller will stopped and will send out a intermittent sound alarm.
Press "SET" and continue step 4.