This kit allows to transform the boiler from room
central heating only to combined production of
domestic hot water and for similar purposes. It
will therefore be possible to couple the boiler to
an external storage tank unit, sold separately.
The kit must be installed by a qualified technician
(e.g. Immergas After-Sales Technical Assistance
Service).
Description for installation.
Proceed as follows to assemble the kit:
- Remove the voltage from the appliance,
removing power from the switch upstream
from the boiler. Cut-off the DHW circuit and
the CH circuit.
- Empty the boiler circuit using the relevant
system draining valve (see boiler instruction
book).
- Disassemble the casing (see boiler instruction
book).
- Mount the fittings (3) on the storage tank unit
return pipes (5) on the storage tank unit flow
pipes (6) as indicated in the figure.
- Remove the cap present on the storage tank
unit return pipe (2) and mount the pipe (5) in
its place, positioning the gasket between them
(4).
Kit composition:
Ref. Qty Description
1
1
Storage tank unit flow pipe
2
1
Storage tank unit return
pipe
3
2
G 3/4" fitting
4
2
24x16x2 flat gasket
5
1
Ø 18 Storage tank return
connection pipe
6
1
Ø 18 Storage tank flow
connection pipe
7
1
Hydraulic unit 3-way motor
8
1
3-way motor blocking clip
9
1
Wiring connector
IE
- Remove the cap present on the storage tank
unit flow pipe (1) and mount the pipe (6) in
its place, positioning the gasket between them
(4).
- Connect the motor (7) onto the three-way
valve and block it using the clip (8) present
inside the kit.
- Connect the connector (9) onto the 3-way
valve motor (7).
Electric connection.
- Open the boiler control panel by loosening the
screws and make it swing downwards.
- Remove the control panel lid by loosening the
fastening screws.
- Connect the wiring of the 3-way motor to the
free 4-way connector present inside the control
panel (see attached wiring diagram).
- Strap the connection cables to the boiler
wiring.
- Re-mount the control panel lid using the
fastening screws.
- Close the control panel, fixing it to the boiler
using the screws present on the same.
- Open the connection box positioned on the
outside of the boiler (below).
- Remove the terminal board resistance (clamps
36 and 37).
2
3
4
5
6
23
With IMMERGAS storage tank:
- Connect the probe present on the storage tank
to the terminal board using a 2 x 0.35mm
bipolar cable at clamps 36 and 37 (see attached
wiring diagram).
With NON IMMERGAS storage tank:
- Position the probe present inside the kit on
the storage tank in the appropriate seat and
connect it to the terminal board using a 2 x
0.35mm
2
bipolar cable, to clamps 36 and 37.
- Close the boiler connection box.
Commissioning.
- Re-mount the casing.
- Open the DHW circuit again and restore the
CH system pressure (see instruction book),
paying attention to have closed the system
draining valve, previously opened.
- Restore the electric power supply to the boiler
in order to take it back to normal operating
conditions.
N.B.: use of the boiler with production of DHW
is described in the boiler instruction book in the
user chapter.