Programming Field 2 : Select Special Mode; Programming Field 3 : Select Can Address; Programming Field 4 : Offset Boost Voltage - Cristec YPO45-12-60/MPPT Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3.3.3

Programming field 2 : Select special mode

BOOST and REFRESH modes are idle by default on the solar charge controller because the solar power source is not
permanent and therefore the MPPT may not complete full battery recharge cycles; which can affect their lifespan. A
solar source is a back-up source, which helps compensate for small battery discharges. The user can, if he likes,
reactivate these modes.
-
The BOOST function allows a faster charging of the batteries. This function is timed in time (see section
3.3.2.) And is automatically inhibited if the battery is charged: shutdown of the BOOST for a battery
current <20% of the nominal current of the MPPT (2A in the case of the Lithium curve Iron Phosphate
with BMS with a minimum time of 10 minutes).
-
The REFRESH function allows to apply a voltage step periodically to maintain the battery, to promote
its equalization and thus prevent possible sulfating.
3.3.4

Programming field 3 : Select Can address

3.3.5

Programming field 4 : offset BOOST voltage

Setting
0
1
2
3
Setting
REGREGULATOR_Frame1
Can address
0
0x0002 9000
0x0002 9001
1
2
0x0002 9002
0x0002 9003
3
4
0x0002 9004
0x0002 9005
5
6
0x0002 9006
0x0002 9007
7
Setting
0
1
2
3
4
5
6
7
REFRESH
mode
OFF
OFF
ON
ON
Setting
REGREGULATOR_Frame1
8
9
10
11
12
13
14
15
12V output
24V output
Offset in mV
Offset in mV
-400
-300
-200
-100
0
100
200
300
BOOST
mode
OFF
ON
OFF
ON
Can address
0x0002 9008
0x0002 9009
0x0002 900A
0x0002 900B
0x0002 900C
0x0002 900D
0x0002 900E
0x0002 900F
-800
-600
-400
-200
0
200
400
600
35
Tabla de contenido
loading

Productos relacionados para Cristec YPO45-12-60/MPPT

Este manual también es adecuado para:

Ypo45-24-30/mpptYpo80-12-40/mpptYpo80-24-25/mppt

Tabla de contenido