Programming Field 1 : Select Type Of Batteries - Cristec YPO45-12-60/MPPT Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

In programming mode, the number of flashes of LED "ON" gives the programming field, the number of flashes of the
green LED "FLOATING/REFRESH" gives the programming value.
Example: field 3 , N = 5
Led "ON"
Led "FLOATING/REFRESH"
3.3.2

Programming field 1 : Select type of batteries

Configuration according to type of batteries 12V or 24V
Description of the battery type
Setting
Opened type bat
0
free electrolyte (wet)
Classic sealed type bat
1
(Sealed Lead)
2
GEL type bat
3
AGM type bat**
4
Spiral type bat
5
Tin calcium lead bat
Wintering or standby sealed
6
7
Stabilized DC power supply
8
SPE1 open type bat
Lithium Iron Phosphate
9
(LiFePO4) with BMS(***)
10
STORMLINE Bat
11
12
13
14
15
Some specific settings are possible – please consult us.
(*) Voltage on + BAT with 10% of the rated current and a tolerance of +/- 1%.
(
)
**
REFRESH is not advised for certain types of AGM batteries
(***) Battery Management System
FLOAT voltage
13.4V/26.8V
13.8V/27.6V
13.8V/27.6V
13.6V/27.2V
13.6V/27.2V
14.4V/28.8V
13.4V/26.8V
bat
12V/24V
13.2V/26.4V
13.8V/27.6V
13.7V/27.4V
12V/24V
Specific
Specific
12V/24V
Specific
13.8V/27.6V
Specific
13.8V/27.6V
Specific
13.8V/27.6V
Maximum
duration of
BOOST voltage
BOOST at
+/- 5% T
14.1V/28.2V
2H
14.4V/28.8V
2H
14.4V/28.8V
2H
14.4V/28.8V
2H
14.4V/28.8V
2H
15.1V/30.2V
2H
13.4V/26.8V
0H
12V/24V
0H
14.8V/29.6V
2H
14.4V/28.8V
6H
14.5V/29V
2H
12V/24V
0H
12V/24V
0H
Programming with RS485
14.4V/28.8V
2H
Programming with CAN bus
14.4V/28.8V
2H
Programming with UNI-DISPLAY-R
14.4V/28.8V
2H
Maximum
duration of
ABSOPTION at
+/- 5% T
BOOST
ABS
4H
4H
4H
4H
4H
4H
0H
0H
4H
1H
6H
0H
0H
4H
4H
4H
34
Tabla de contenido
loading

Productos relacionados para Cristec YPO45-12-60/MPPT

Este manual también es adecuado para:

Ypo45-24-30/mpptYpo80-12-40/mpptYpo80-24-25/mppt

Tabla de contenido