In programming mode, the number of flashes of LED "ON" gives the programming field, the number of flashes of the
green LED "FLOATING/REFRESH" gives the programming value.
Example: field 3 , N = 5
Led "ON"
Led "FLOATING/REFRESH"
3.3.2
Programming field 1 : Select type of batteries
Configuration according to type of batteries 12V or 24V
Description of the battery type
Setting
Opened type bat
0
free electrolyte (wet)
Classic sealed type bat
1
(Sealed Lead)
2
GEL type bat
3
AGM type bat**
4
Spiral type bat
5
Tin calcium lead bat
Wintering or standby sealed
6
7
Stabilized DC power supply
8
SPE1 open type bat
Lithium Iron Phosphate
9
(LiFePO4) with BMS(***)
10
STORMLINE Bat
11
12
13
14
15
Some specific settings are possible – please consult us.
(*) Voltage on + BAT with 10% of the rated current and a tolerance of +/- 1%.
(
)
**
REFRESH is not advised for certain types of AGM batteries
(***) Battery Management System
FLOAT voltage
13.4V/26.8V
13.8V/27.6V
13.8V/27.6V
13.6V/27.2V
13.6V/27.2V
14.4V/28.8V
13.4V/26.8V
bat
12V/24V
13.2V/26.4V
13.8V/27.6V
13.7V/27.4V
12V/24V
Specific
Specific
12V/24V
Specific
13.8V/27.6V
Specific
13.8V/27.6V
Specific
13.8V/27.6V
Maximum
duration of
BOOST voltage
BOOST at
+/- 5% T
14.1V/28.2V
2H
14.4V/28.8V
2H
14.4V/28.8V
2H
14.4V/28.8V
2H
14.4V/28.8V
2H
15.1V/30.2V
2H
13.4V/26.8V
0H
12V/24V
0H
14.8V/29.6V
2H
14.4V/28.8V
6H
14.5V/29V
2H
12V/24V
0H
12V/24V
0H
Programming with RS485
14.4V/28.8V
2H
Programming with CAN bus
14.4V/28.8V
2H
Programming with UNI-DISPLAY-R
14.4V/28.8V
2H
Maximum
duration of
ABSOPTION at
+/- 5% T
BOOST
ABS
4H
4H
4H
4H
4H
4H
0H
0H
4H
1H
6H
0H
0H
4H
4H
4H
34