6. If you make a connection with a lexible metal hose, locate a seal
between the main gas pipes.
7. The inner diameter of the lexible hose, which the butane hose
nozzle is connected, should be 6mm for the house-type gas tubes. The
inner diameter of the lexible hose, which the natural hose nozzle is
connected, should be 15mm.The hose should tightly be itted to the
hose nozzle by squeezing with a clamp. The hose should be replaced
before its last expiry date.
8. Caution! Make the oven connection to the gas inlet valve, the hose
length must be short and be sure that there is no leakage. The lexible
hose used should not be longer than 125 cm for safety.
9. Re-inspect the gas connection.
10. When placing your oven to its location, ensure that it is at the
counter level. Bring it to the counter level by adjusting the feet if
necessary.
DO NOT MAKE GAS HOSE and ELECTRICAL CABLE OF YOUR OVEN GO
THROUGH THE HEATED AREAS, ESPECIALLY THROUGH THE REAR SIDE OF
THE OVEN. DO NOT MOVE GAS CONNECTED OVEN. SINCE THE FORCING
SHALL LOOSEN THE HOSE, GAS LEAKAGE MAY OCCUR.
ELECTRICAL WIRING SCHEME
All manuals and user guides at all-guides.com
220-240V~50/60Hz
220-240V~50/60Hz
Neutral
Neutre
Live
Earth
Phase
Terre
Erdung
H05 VV-F 3G 4mm² H05 VV-F 5G 1.5mm² H05 VV-F 4G 1.5mm² H05 VV-F 3G 1.5mm²
GB
380-415V 3N~50/60Hz 380-415V 2N~50/60Hz
400V 3N~50/60Hz
400V 2N~50/60Hz
L3
L2
Neutral
Neutre
L2
Earth
L1
L1
Terre
Erdung
37
220-240V~50/60Hz
220-240V~50/60Hz
Neutral
Neutral
L1
Neutre
Neutre
Earth
Earth
Terre
Terre
Erdung
Erdung