USE
Before fi rst use and after every gas cylinder change, gas delivery system
must be purged of air before igniting! To do this, turn the control knob anti-
clockwise to the pilot setting. Press knob in and hold for about 2 minutes
before attempting ignition.
To light the pilot
•
Check all connections prior to each use.
•
Turn on main gas supply at source.
•
Press to turn control knob anti-clockwise to PILOT, see right photo.
•
Hold knob depressed, press IGNITION button repeatedly until pilot fl ame
is lit, then continue to hold the knob depressed for 10 seconds until the
pilot remains it after releasing knob.
•
If pilot fails to ignite or alight, press to turn knob clockwise to OFF and
repeat.
To light the appliance
•
The pilot should be lit and the knob set to PILOT.
•
Hold knob depressed gently and turn anti-clockwise to HIGH.
•
When the appliance glows lit, turn knob clockwise from HIGH to LOW as
needed.
Re-lighting
•
Turn control knob to OFF.
•
Wait at least 5 minutes, to let gas dissipate, before attempting to re-light
pilot.
•
Repeat the "Lighting" steps.
EN