PLAN CABINET CUTOUTS
CAUTION:
BEFORE CUTTING HOLE IN CABINET FOR
!
DUCTWORK, check for interference with floor
joists, wall studs, electrical wiring, or plumbing.
INSTALLATION
CENTER LINE
6 "
7
/
8
HOLE
1 "
7
/
8
FOR
2" X 19¼"
DUCT
19¼"
2"
6"*
INSIDE
1½"
CABINET
FLOOR
(When using Remote Discharge Plate - Hole is
Use the dimensions in the above illustration to help plan how and
where to provide duct access through your cabinet. Generally, 1-7/8"
x 19" rectangular duct will be used through left, right, and back of
cabinet - while 8" round duct will be used through cabinet floor.
For left, right, or rear exhaust:
Allow at least 18" for transition and elbow or blower.
For left / right exhaust:
A 30" deep cabinet is recommended to align properly with flex
blower. Flex blower can be mounted to rear cabinet wall or to a
platform / frame (not provided) on the base of the cabinet floor.
(See flex blower instructions).
Cabinet depths of 24" to 30" are required - depending on the
type of cooking appliance.
PLAN THE WIRING
1. This downdraft blower using the Flex Blower (purchase
separately) draws 3.0 Amps and requires a 120 VAC, 60 Hz
circuit. If using a remote blower (purchase separately), the
system draws 6.0 Amps (max.) and requires a 120 VAC, 60
Hz circuit.
2. The unit has a 30 in. long power cord with a 3-pronged plug.
Plan to provide a grounded outlet in a location which will allow
the unit's power cord to reach.
3. Install electrical box according to local codes.
All manuals and user guides at all-guides.com
INSIDE
CABINET BACK
26¾"
19¼" centered
6"*
2"
HOLE FOR 8" or
10" ROUND DUCT
(*Adjustable 6" Left and 6" Right)
adjustable 6" Left and 6" Right from
Installation Center Line.)
Models D49M30SB • D49M36SB • D49M48SB
PREPARE THE DOWNDRAFT
Electrical panel
can be mounted
remotely.
Installations ducting through front panel opening only:
1. Place the downdraft on its back on a table or flat work surface.
2. Loosen the HEX NUTS on the CLAMP CHANNEL and remove
the FRONT PANEL COVER.
COVER
PLATE
FRONT
PANEL
If blower
discharge is
down,
electrical
panel must be relocated.
See Step 6.
Installations using FLEX BLOWER only:
(Purchase Model PF6 Flex Blower separately.)
3. Determine its location on FRONT PANEL and whether it will
discharge to the left, right, or down.
Use a combination of COVER PLATES (3" and/or 6" wide) to
close the opening on side(s) of blower.
Slide the blower and cover plates between the LOWER
CHANNEL and the clamp channel. Tighten the hex nuts to
secure blower and panels in place.
FRONT PANEL COVER
CLAMP
CHANNEL
#10-24 HEX
NUTS
FLEX
BLOWER
COVER
PLATES
LOWER
CHANNEL