3.1.3
2-channel receiver
Fig. 3
This receiver has two normally open contact relays:
•
Relay contact R1/channel 1: A.3/A.4
•
Relay contact R2/channel 2: A.5/A.6
Each of these contacts can only be connected to the touch mode.
The normally open contact to be adjusted in interaction with the
remote control unit is selected with the button 3 and the LEDs C.1
and C.2.
The receiver has a AC/DC 12-24 V supply:
•
A.1: AC/DC 12-24 V
•
A.2: Ground
This receiver is accommodated by a housing which must be
installed in a switch box.
06|2020
Description