Troubleshooting Guide - Porter Cable PGN350 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

All manuals and user guides at all-guides.com

TROUBLESHOOTING GUIDE

PROBLEM
Engine will not
1.
start
2.
3.
4.
5.
6.
7.
No electrical
1.
output
2.
3.
4.
5.
Repeated
1.
circuit breaker
2.
tripping
Generator
1.
overheating
2.
Handle does
1.
not fold with
ease.
D28733
CAUSE
Low on fuel or oil.
Ignition switch in "Off"
position.
Faulty spark plug.
Choke in wrong position.
Fuel shut-off valve in
closed position
Unit loaded during start-
up.
Spark plug wire loose.
Faulty receptacle.
Circuit breaker kicked
out.
Defective capacitor.
Faulty power cord.
GFCI switch breaker
kicked out
Overload
Faulty cords or
equipment
Generator overloaded.
Insufficient ventilation.
Area where handle
rotates in brackets not
lubricated.
20- ENG
CORRECTION
1.
Add fuel or oil.
2.
Turn to "ON" position
3.
Replace spark plug.
4.
Adjust choke accordingly.
5.
Open fuel shut-off valve.
6.
Remove load from unit.
7.
Attach wire to spark plug.
1.
Have Service Center
replace.
2.
Depress and reset.
3.
Have Service Center
replace capacitor.
4.
Repair or replace cord.
5.
Depress and reset
1.
Reduce load.
2.
Check for damaged, bare,
or frayed wires on
equipment. Replace.
1.
Reduce load.
2.
Move to adequate supply
of fresh air.
1.
Lubricate area with light
oil.
2.
Loosen bolt going thru
handle on both sides.
Tabla de contenido
loading

Tabla de contenido