• Do not store spare LP-gas cylinder under or near the appliance.
• Never fill the cylinder beyond 80 percent full.
• If the information beyond is not followed exactly, a fire causing death or serious injury may occur.
• Minimal clearance from sides and back of the unit to combustible construction, 24 inches from the sides
and 24 inches from the front.
• Do not use the appliance under overhead combustible surfaces.
• CAUTION: The gas pressure regulator provided with this appliance must be used. Replace only with the
regulator Model No. A300USL. This regulator is set for an outlet pressure of 11 iwc.
• Turn o the LP supply at cylinder when appliance is not in use.
• This appliance is not intended for commercial use.
• The instruction manual contains important information necessary for the proper assembly and safe use
of the appliance.
• Read and follow all warnings and instructions before assembling and using the appliance.
• Follow all warnings and instructions when using the appliance.
• If instruction or parts are missing contact support.ooni.com
Always route the gas hose away from the oven. The hose must not touch the oven body.
WARNING Hose pipe can be a tripping hazard
Hose pipe can be a tripping hazard
Coloca siempre el tubo flexible de gas alejado del horno. El tubo flexible no debe tocar el
cuerpo del horno.
ADVERTENCIA El tubo flexible puede generar riesgo de tropiezos
Éloignez toujours le tuyau à gaz du four. Le tuyau ne doit pas toucher à la structure du four.
MISE EN GARDE Le tuyau peut présenter un risque de trébuchement
24"
35.4"
12
Manufacturer: Ooni Limited
Model: Ooni Koda 12
ANS Z21.89-2017 CSA 1.18-2017 Outdoor Cooking Specialty Gas Appliance
For outdoor use only. If stored indoors, detach and leave cylinder outdoors.
Propane
Rate Input (BTU/H)
Components
Orifice Size
Main Burner
0.74mm
13300
LIGHTING INSTRUCTION - TO LIGHT THE BURNER
Read all instructions before lighting
• Make sure the control knob is in OFF position,
and then turn the liquid propane cylinder valve
ON by slowly turning counterclockwise.
• Push in and slowly turn the control knob
anticlockwise until you hear a click and the
burner ignites.
• If burner doesn't light within 5 seconds, turn the
knob OFF, wait 5 minutes and repeat the
lighting.
Ooni Limited, Unit 5, Bishopsgate Business Centre, 189 West Main
Street, Broxburn, UK, EH52 5LH
Fabricante: Ooni Limited
Modelo: Ooni Koda 12
Ooni Limited, Unit 5, Bishopsgate Business Centre,
189 West Main Street, Broxburn, Reino Unido, EH52 5LH
• No almacenes la bombona de gas LP de repuesto debajo o cerca del aparato.
• Nunca llenes la bombona más del 80%.
• Si no se siguen al pie de la letra las indicaciones anteriores, puede producirse un
incendio que cause la muerte o lesiones graves.
• La distancia mínima entre los laterales y la parte trasera de la unidad a la
construcción combustible debe ser de 24 pulgadas por los lados y 24 pulgadas
desde la parte delantera.
• No utilices el aparato debajo de superficies elevadas que sean combustibles.
• ADVERTENCIA: Es necesario utilizar el regulador de presión de gas suministrado
con este producto. Sustitúyalo únicamente por el regulador modelo A300USL.
Este regulador está ajustado para una presión de salida de 11 iwc.
• Cierra el suministro de LP en la bombona cuando el aparato no esté en uso.
•Este aparato no está diseñado para uso comercial.
• El manual de instrucciones contiene información importante necesaria para el
montaje correcto y el uso seguro del aparato.
• Lee y sigue todas las advertencias e instrucciones antes de montar y utilizar el
aparato.
• Sigue todas las advertencias e instrucciones cuando utilices el aparato.
• Si faltan instrucciones o piezas, ponte en contacto con support.ooni.com