Attention! The fitting must be installed, flushed and
tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in
position on the basin.
3. Slip the slide washer, washer and collar nut
over the hose and threaded base and tighten
the collar nut by hand.
4. Tighten screws.
5. Connect the supply pipes to the isolation
valves;
cold right - hot left.
6. Connect the pull rod to the pop-up waste.
The hot and cold supplies must be of equal
pressures.
Operation
The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
Technical Data
T h i s
m i x e r
s e r i e s - p r o d u c e d
waterdimmer
(flow limiter)
®
Rate of flow with waterdimmer:
Rate of flow without waterdimmer: 14 l/min 0,3 MPa
Operating pressure:
Recommended operating pressure: 0,1 - 0,5 MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temperature: 65° C
Test certificate 38020000:
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0,15 MPa.
6
English
w i t h
7 l/min 0,3 MPa
max. 1 MPa
1,6 MPa
max. 80° C
WRAS
If the continuous water heater causes any problems or
there is not enough flow of water, the waterdimmer
(6a) located behind the aerator must be removed.
To adjust the hot water limiter on single lever mixers,
please see page 13.
No adjustment is necessary when using a continuous
flow water heater.
Spare parts (see page 3)
1
handle
1.1 screw cover
1.2 hollow set screw M6x10 DIN916 96029000
2
flange
3
nut
4
cartridge cpl.
5
seal
6
aerator cpl.
7
fixing set
8
connection hose470 mm
9
pop up rod
10 supply pipe 450 mm
11 ball joint
12 aerator cpl.
Special accessories
X
special tool set
(order as an extra)
®
38094000
96762000
96763000
97209000
96764000
95008000
97370000
13961000
96321000
96657000
96638000
96050000
94005000
58085000