Riello Hi, Comfort 100 Manual Instalador Y Usuario página 104

Ocultar thumbs Ver también para Hi, Comfort 100:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 188
Parameter
tSEt
ESC
MODE
tFLO
ESC
MODE
trEt
ESC
MODE
tdH
ESC
MODE
Description
Heating
delivery
the Hi, Comfort T100 (shown only if the
Hi, Comfort T100 has received a heat-
ing request). The value calculated by the
Hi, Comfort T100 may differ from the real heat-
ing delivery setpoint delivered by the boiler, if
the minimum boiler heating setpoint parame-
ter is higher than this value.
EXAMPLE:
The heating delivery setpoint calculated by the
Hi, Comfort T100 is 30°C, the minimum boiler
heating setpoint parameter is 40°C, the real
heating delivery setpoint delivered by the boiler
is 40°C.
Temperature read by the boiler heating de-
livery probe (available with OTBus connection
between the WiFi Box and the boiler or the RF
receiver and the boiler or the Hi, Comfort T100
and the boiler, if provided for by the OTBus pro-
tocol).
Temperature read by the boiler heating return
probe (available with OTBus connection be-
tween the WiFi Box and the boiler or the RF
receiver and the boiler or the Hi, Comfort T100
and the boiler, if provided for by the OTBus pro-
tocol).
Temperature read by the boiler DHW probe
(available with OTBus connection between
the WiFi Box and the boiler or the RF receiv-
er and the boiler or the Hi, Comfort T100
and the boiler, if provided for by the OTBus
protocol).
104
setpoint
calculated
by
Tabla de contenido
loading