Thank you for purchasing this safe. We advise you to read the instruc-
tions before you install and use the safe to prevent its improper use from
making the guarantee void.
A. CHARACTERISTICS OF THE PRODUCT
FRONT DIAGRAM OF THE SAFE
1. KEY.
2. PLASTIC COVER – EMERGENCY LOCK.
3. NUMERIC KEYPAD.
B. OPENING AND CLOSING THE SAFE
B.1. FIRST TIME THE SAFE IS OPENED AND INSTALLATION OF THE
BATTERIES
• Remove the small plastic cover on the front panel by pressing the left
side of the cover inward
• Insert the emergency key into the key hole and turn it counter-clockwise
direction. Insert the user key and turn it to open the safe.
• In order to function, the safe needs 4 x 1.5 V alkaline batteries that are
placed at the back of the door.
• Open the cover of the battery holder and place the batteries taking into
consideration their polarity.
• On completion of this process the electronic system will be activated.
B.2. PROGRAMMING OPENING CODES
This safe has 2 opening codes: User code and master code.
The initial user opening code is 159. For your security, it´s important
that you change them and configure the codes you desire. To change it,
proceed in the following manner:
• Programming user code.
- Press the reset button (on the left-side of back of door) .The yellow
light will be on.
- Input any 3-8 digits you want, press "#" to confirm. 2 beeps will
indicate the personal code has been accepted and stored.