1 Operating instructions MystMaker III
The MystMaker III is a device that sprays water through an ultrasonic technique that creates real water mist and therefore air humidity. The MystMaker III is designed for use
indoors and can be used for numerous versatile applications such as an atmospheric effect for room fountains, spring fountain, as a humidifier for terrariums or just to create
a pleasurable room atmosphere. The mist creator can also be used to swim on the surface of the water using the aid of the swim ring that is provided in the scope of delivery.

Technical data

Art.-No. EU
Art.-No. UK
Transformer
Nominal voltage
Nominal capacity
Length of the cable
Ultrasonic frequency
Creation of mist
Minimal immersion depth
Water temperature
Membrane (disc)
Scope of delivery
Safety regulations
The voltage supply has to comply with the product specifications. The device should possess a residual current protection switch (FI Switch) and be operated with a nominal fault
voltage of ≤ 30mA. If necessary, inform yourself as to which connection regulations you have to apply with your local electricity supplier.
• The MystMaker III must only be operated using the safety transformer that has been provided.
• Take care that the device connections (plug, socket) are always kept dry.
• Always switch off the power supply before touching or removing the MystMaker III from the water.
• Do not hold any parts of your body such as your finger in the water fountain of the MystMaker III and place the device in a position so that no house pets can come into contact with it.
• Take care that no water sensitive objects are situated within of 30 cm of the MystMaker III.
• Remove the plug from the socket when the MystMaker III is not going to be operated over a longer period.
• Never use the cable to carry the MystMaker III and never pull it out of the water using the cable.
A replacement of the electric cable is not possible. The device has to be disposed of if the cable is damaged.
Initiating
• Place the MystMaker III into your room fountain or water container so that it is covered with water.
• Connect the provided transformer on to the supply line of the MystMaker III and also in an adequate mains socket.
• When the control lamp of the MystMaker III illuminates, the device is activated and creates water mist. If the water level falls below the minimum water level, the water level
control sensor switches the MystMaker III off automatically.
• The ceramic discs (membrane) have a limited life span and has to be replaced after approx. 3000 hours. At the latest, a replacement is necessary when mist is not created when the
control lamp illuminates.
Replacement of the membrane
The ceramic disc (membrane) is a wearing part. If the misting effect is reduced or does not function at all, .
the ceramic discs have to be replaced. This can be acquired as replacement part (set with 3 pieces each) at your Ubbink specialist dealer (Article number 1387095).
• For replacement, use the special tool (1) that has been provided.
• Remove the plug of the mains adapter from the socket and remove the MystMaker III from the water.
• Remove any possible lime residues in the area of the ceramic disc (membrane) using water with vinegar.
• Make sure that the device has been completely dried before unscrewing it.
• Turn the threaded ring (2) in a clockwise direction using the special tool (1).
• Now remove the ceramic disc carefully.
• The ceramic disc is very sensitive. Now place the new ceramic disc carefully into the MystMaker III using the correct side with the circle markings underneath (5b). Take care that the
rubber seal (4) has been set correctly and is not damaged.
• Now carefully screw the treaded ring (2) back Into the MystMaker III in a clockwise direction and initiate the MystMaker III once again.
2
Guarantee
We give a guarantee of 2 years against proven material and manufacturer faults that apply from the date of purchase: The original sales receipt has to be presented as proof of
purchase if claims are made on the guarantee. Any complaints that do not fall under the guarantee are where they are caused by faults that are because of disregard of the safety
regulations through the mounting and user faults, lack of care, influence of frost, improper repair service, resorts of violence, third party negligence, overstressing, mechanical
damages or through the exposure of foreign bodies. All complaints of partial damages and / or problems that have been caused by worn parts are also excluded from the guarantee as
well as damage by plants and animals.
Environmental Protection
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist.
Check with your Local Authority or retailer for recycling advice.
1387090
1387590
230 VAC 24 VAC
230 VAC / 50 Hz
84 W
1 x 2m + 1 x 10 m
1700 ± 40 KHz
approx. 900 ml/h
55 -65 mm
0 – 40 ° C
Ø 20 mm / > 3.000 h
MystMaker III incl. 3 ceramic membrane discs (membrane) Ø 20 mm, floating body, Safety transformer 24 VAC, special tools.