Gewiss Chorus GW 20 476 Manual De Instrucciones página 22

Idiomas disponibles
  • ES

Idiomas disponibles

All manuals and user guides at all-guides.com
The interface has 6 output channels, each permitting a certain command on the burglar
alarm system. From the logic standpoint, the interface is seen as a 5-channel binary
actuator (1..5) which, upon receiving an on/off type of command, runs the specific
command assigned to that channel on the system and returns on/off status information
on the run command.
The following table lists available commands and status information provided by the
burglar alarm system control panel.
Channel
88996
ON = total arming of the burglar alarm system
1
OFF = total disarming of the burglar alarm system
ON = partial arming 1 burglar alarm system
2
OFF = no effect
ON = partial arming 2 burglar alarm system
3
OFF = no effect
ON = trigger transmission alarm status
4
OFF = trigger transmission alarm status
ON = trigger transmission enable arming
status
5
OFF = trigger transmission enable arming
status
Status information is updated and sent to the bus when the corresponding command is
run and automatically at each change in status.
Channel 6 is dedicated to saving/running scenes (max. 8). For security reasons, only
system arming status can be saved in a scene.
Channel
6
Commands can sent via the Easy control panel (GW 12 771TB/VT/VA), via the Easy push-
button panel (i.e. GW 10 752), with buttons connected to other contact interfaces
(GW 90 834) or from remote via the GSM Easy remote control unit (GW 90 861).
1) partial arming 1 corresponds to burglar alarm system "day mode arming"
2) partial arming 2 corresponds to burglar alarm system "night mode arming"
3) the system cannot be armed when no arming (total, partial 1, partial 2) is enabled. Arming is enabled when
at least one arming is possible.
GENERAL DESCRIPTION
Easy functions (E-mode)
Command
3
Command
Scene save/run
18
Status information
ON = system on
OFF = system off
1
ON = splitting 1 on
OFF = splitting 1 off
2
ON = splitting 2 on
OFF = splitting 2 off
ON = alarm on
OFF = alarm off
ON = system enabled
for arming
OFF = system not enabled
for arming
3
loading