1. INSTALLATION

!
The support surface must be flat and smooth. The IP sealing gaskets must be present and intact
in the base (1) and in the body ( 5).
1. Prepare the connecting cables and install the base. Follow the instructions given in  1.
2. Connect the XKPR to the SPINet terminals of the Door Controller board. Follow the instructions given
in 2 and 3.
- Remove at least 1 cm of the conducting sheath. Only the conductors and not the sheath must be
present in the IP gaskets. Otherwise, the IP gasket will leak.
- Wires having a maximum section of 0.5mm
3. Configure the jumper according to the type of reader, A or B. ( 4 ).
4. Turn power on to the board:
- The XKPR keypad lights up after a few seconds.
5. Make sure that the keypad and the proximity sensor are working correctly.
6. Fasten the body to the base (5). Install the cover ( 6).
!
Close or open the reader in the absence of power!

2. XKPR

The XKPR reader is included in the FAAC range of access control devices.
The XKPR allows a tag to be read or numeric codes to be entered that are restricted to each user. In order
to be valid, each user code must be stored on the Door Controller.
!
- In order to restrict access, it is important not to allow the stored codes to be known by unau-
thorised persons. Whenever the user is given a code, one should recommend that he/she keeps
it confidential.
The XKPR must be connected to a DOOR Controller in order to work.

3. USAGE

!
The user must follow the safety instructions and recommendations given by the installer.
In order to restrict access, the user must not give his code to other people.
L
L
Always press one button at a time (if 2 buttons are pressed at the same time, neither is recogni-
sed). The timeout between the pressing one button and another is 5 s.
The installer must provide users with information for use.
Blind and Visually Impaired Users: these users can recognise buttons using Braille.
Warnings
Green
 (OK)
 (error)
To type in a code, enter the numbers that make up the code in sequence, pressing one key at time. When
E
finished press key
.
#
Pressing the
key will cancel the last digit that was entered.
L L
The operation of the Buzzer and the Backlight is configurable via the SW Keydom.
XKPR
Buzzer
Red
1.0 s 2 
0.5 s
1
can be placed in the connector on the XKPR
2
14