System is operating under pressure!
Incorrect installation may damage the maintenance unit/maintenance equip-
ment and cause serious injury.
Before commissioning, check that all connections, ports, and maintenance
u
equipment have been correctly installed.
5.1 Connecting the oil separator to the tubing system or
maintenance unit
The ideal mounting position is at the end of the air circuit.

5.1.1 Assembly without mounting bracket

See g Fig. 1, g Fig. 2.
Screw the tube into the (a) G1/2 – G1 connection.
u

5.1.2 Assembly with mounting bracket

See g Fig. 1, g Fig. 2.
1. Mount the bracket to the oil separator with two hexagon socket screws.
2. Mount the oil separator to the wall with two screws.
3. Connect the compressed air to the (a) G1/2 – G1 connection.

5.2 Draining oil manually

See g Fig. 1.
1. Turn the condensate drain (b) 1/4 turn counterclockwise and drain the bot-
tom section.
2. Close the condensate drain (b) again.

5.3 Mounting the tubing for controlled drainage

See g Fig. 1.
A tubing (c) can be plugged onto the oil drainage fitting at the bottom for con-
trolled oil drainage.

6 Maintenance and repairs

6.1 Cleaning and servicing

• Close all openings with suitable safety devices so that no cleaning agent can
enter into the system.
• Never use solvents or aggressive detergents. Only clean the product using a
slightly damp cloth. Only use water and, if necessary, a mild detergent.
• Do not use high-pressure cleaners for cleaning.
• Do not use compressed air for cleaning (blowing off) the maintenance unit or
equipment.

6.2 Replace filter element:

See g Fig. 3.
System is operating under pressure!
Opening the system when it is under pressure can result in personal injury and
cause damage to the maintenance unit/device.
Please ensure that the system is not under pressure before you open the
u
reservoir.
Filters become contaminated with use and must be changed annually. This, how-
ever, is only a recommendation, since the change intervals depend on the quality
of the compressed air and the amount of air throughput.
1. To change the filter element, turn the bottom section slightly counterclock-
wise (a) and pull it off towards the bottom (b).
2. Remove the filter element (c, d).
3. Then change the filter element (e, f).
4. Screw the new filter element into the oil separator (g, h).
5. Re-mount the bottom section (i, j).
AVENTICS™ MU1 | R412028656-BAL-001-AA | English
CAUTION
CAUTION
To place your order use the material numbers listed below. If necessary contact
one of our addresses (see back cover for contact data).
Wear part
Coalescing Filter
Coalescing Filter

7 Decommissioning, disassembly, exchange

Danger of injury in case of disassembly or replacement under pressure or
voltage!
Disassembling or replacement when under pressure or electrical voltage may
lead to injuries and damage to the product or system components.
1. Make sure that the relevant system part is not under pressure or voltage be-
fore disassembling the product or exchanging parts.
2. Protect the system against being restarted.

8 Disposal

Dispose of the product and fluid in accordance with the national regulations in
your country.

9 Troubleshooting

Malfunction
Possible cause
No flow
Soiled filter
Pressure/flow level is not reached
Soiled filter
or drops off slowly.
Selected filter is too small Select larger filter

10 Key Technical Information

Maximum permissible pressure and thread connection are indicated on the prod-
ucts.
General data
Mounting orientation
Further technical data can be found in the online catalog.

11 Appendix

Fig. 1: Oil separator
Size
Material number
G1/2 – G3/4
R412028131
G1
R412028132
CAUTION
Remedy
Clean or replace filter
Clean or replace filter
Vertical
P
1
a
b
c
8