3. Assembly of the control cabinet

3.1

Selecting the location

When selecting the location for the control cabinet, the following must be considered:
The control cabinet must be mounted above the highest water level in the tank to avoid overflow-
ing and water intake by gravity in case of an accident.
The system generates noise! When operating, the air compressor generates continuous noise
(comparable to that of a freezer).
The machine cabinet requires a separately protected electrical connection (16 amp, slow blow).
The electrical connection serves as a mains disconnecting device and must be easily accessible
at all times. Additional electrical fixtures on the same fuse may disrupt operation.
The location of the control cabinet must be a dry, cool and well-ventilated room. The cabinet, in
particular the ventilation vents, must not be covered and must be freely accessible for mainte-
nance work.
The air hoses should be no longer than 20 metres.
3.2

Technical Data

Model:
IP20
Material:
PP
Color:
black
Shutting:
Screw lock centered at the front cover
Electrical connection:
Back-up fuse required on site
1 ~ 230V, 50 Hz
Connections at the cabinet:
Compressed air nozzles: 2 x 19 mm
Connection cable with plug type E+F
3. Assembly of the control cabinet
280
420
Dimensions of the PP Cabinet
/