NEW CONSTRUCTION INSTALLATION INSTRUCTIONS
BEFORE INSTALLATION
WARNING: RISK OF ELECTRIC SHOCK! Ensure the
electricity to the wires you are working on is shut off.
Either remove the fuse or turn off the circuit breaker
before removing the existing bath fan or installing the
new one.
1. Place the fan housing (A) next to a ceiling joist.The fan
housing (A) should be level and perpendicular to the joist.
Allow for thickness of ceiling board used in your application.
Position the fan housing (A) so the bottom edge of the fan
housing (A) is flush with the ceiling board. Do not flush mount
the fan housing (A) to the bottom of the joist.
2. Before mounting the fan housing (A) to the joist, remove the
duct connector for easier access to the mounting hole on that
side of the fan housing (A).
Remove the duct connector by inserting a flathead screw-
driver between the duct connector and the metal of the fan
housing (A), and gently prying the duct connector away from
the fan housing (A).
3. Mount the fan housing (A) to the joist by inserting wood
screws (AA) into the holes indicated on the metal tabs of the
fan housing (A). Tighten the wood screws (AA) until the fan
housing (A) is firmly secured to the joist.
A
4. Reattach the duct connector by hooking the connector on one
side of the metal flange on the opening in the fan housing (A)
and then pressing on the other side to snap the duct connector
into place. Ensure that all four metal flanges on the fan
housing (A) are inside the plastic duct connector when
it is replaced.
All manuals and user guides at all-guides.com
6
1
2
Duct connector
3
A
4
Duct connector
A
A
A
AA
A
HomewerksWW.com