5.4 Temporary conversion of the system to manual operation.
The module should be dismounted as described in Section 5.2.
Once the supply system is out, unplug the wires in the control box (L-N) that supply the electronic
module.
Disconnect the wires from terminal (J10) on the electronic module and connect thme to each other
with a bridge between these two terminals.
Remove screw (3) (APPENDIX 1 - Fig. 4), and pull the pawl (5) upwards, then (see APPENDIX
1 - Fig. 5) remove the pin (6) in the direction of the arrow sale, remove part (7), leaving the valve
in position for installing the handle.
To install the handle, position the handle* (14) (APPENDIX 1 - Fig. 6) such that the triangle on
the bell shaft always coincides with the handle positioner (9). Once it is installed, the pin* (10)
can be inserted .
In the event that there is an electrovalve in the drainage system, turn the lever (APPENDIX 1 – Fig.
9 - detail 1) to position manual.
The 3 position switch, On "II", Hi "I" should be in the "I" position.
* Supplied as spare parts.
5.5 How to change the valve from manual to automatic operation.
Remove the pin (10) (APPENDIX 1 - Fig. 6), remove the handle (14) and install the part (7)
(APPENDIX 1 - Fig. 5). This is accomplished by orienting the mark (A) such that it coincides with
the triangle (APPENDIX 1 - Fig. 6). Once fi tted in place, the pin (6) (APPENDIX 1 - Fig. 5) should
be inserted, which should be centred along its length. Then install the part (5) (APPENDIX 1 - Fig.
4). Slot the inside notch (15) into the mark (16). See assembly illustration in APPENDIX 1, fi g.7.
Which should be well-positioned (it only has one mounting direction). Insert the screw (3) and
screw in. It should not be fully tightened since it has to be loosened in order to orient it with the
pin (4) on the motor assembly. At this point, it is now possible to install the module assembly as
described in the valve module installation process.
In the event that there is an electrovalve in the drainage system, turn the lever (APPENDIX 1 – Fig.
9 - detail 1) to position nº2 (automatic).
Control box: The 3 position switch, On "II", Hi "I" should be in the "II" position.
6. IDENTIFYING ERRORS
The situation might arise that owing to the a problem in installation (air working in depression) the
time needed to prime the pump is greater than that programmed for the wash and rinse cycles,
something that would cause the valve to start this operational mode without the fi lter working correctly.