Verify that the automatic filter cleaning works.
Maintenance
It is important that the cyclone's filters are replaced as they can no longer be cleaned effectively. The intervals between the
changes depend entirely on the material being sucked, the flow of the system and the operating time.
Filter replacement
Filters must be changed at least once a year. Depending on operating conditions and shifts, they may need to be replaced more
often. Do not expose unprotected dust to hazardous dust.
Filter replacement may only be performed by trained personnel. Use a protective mask and suitable equipment.
1. Turn off and lock the vacuum producer's circuit breaker.
2. Put on safety gear.
3. Empty the compressed air-tank.
4. Remove the cover of the dust separator.
5. Remove the filters and put them in a plastic bag. Seal the bag.
6. Vacuum filter plate and casing.
7. Put the new filters in place, and put the cover back on the dust separator.
Explosion panel
Information regarding maintenance of the explosion panel can be found in a separate document from the supplier.
Technical data
Technical data
H x W x D [mm]
Weight [kg]
Inner diameter [mm]
Inlet [mm]
Outlet [mm]
Maximum recommended air flow [m
Max temperature filter unit [°C]
Filter
Filter area [mm]
Filter classification
Degree of separation [%]
Container [l]
Max temperature filter [°C]
Filter cleaning with reverse air pulse
Compressed air [bar]
Hose connection [mm]
Art no.
Pressure tank
Filter cyclones
428801
11000, 11000 X, 11000 EX, 21000, 21000 EX
434201
32000, 34000, 34000 X, 34000 EX
S11000
1775 x 675 x 625
65
Ø 477
Ø 108
Ø 108
3
/h]
1000
70
8,4
EN 60335-2-69, Klass M
99,9
50
130
4
6/8
1103 (24 V AC)
110300 (24 V DC)
110302 (24 V AC Stainless)
S11000, Art no. 99051-A
Recommended pressure
4 bar
4 bar
Maximum pressure
7 bar
5 bar
13