Always carry out a filter cleaning and empty the compressed air tank before detaching the collection device from the filter unit. All
handling of the collected material must comply with the relevant regulations.
Inspection
Regularly check the device for damage and wear. If damage occurs, these must be repaired by a Dustcontrol service technician
or by a service workshop authorized by Dustcontrol.

Intended use

Dustcontrol's filter cyclones are used to filter dust that arises in an industrial environment.
The filter cyclone is connected to a piping system provided by Dustcontrol. The system is in turn connected to a vacuum
generator.

Functional description

S11000 purifies the air in two steps.
In the first step, dust is separated in the cyclone. The air is taken in tangentially in the filter cyclone and begins to circulate
strongly. This causes the particles to be pressed out against the mantle surface and then fall to the bottom.
In the second step, the air passes through a filter that separates 99.9% of particles from size 0.3 µm. Normally, the air is then led
out of the room.
The filters are automatically cleaned after a signal from the control system by means of an air pulse in the opposite suction
direction. It is a very effective cleaning while being gentle on the filters.

Installation

It is possible to replace the standard container with a widening chassis that allows the dust to collect in a container instead; see
chapter Accessories.
The following describes how to assemble the product:
1. Mount the bottom cone on the legs.
Adjust the height of the legs according to which discharge cone / container is selected.
2. Mount the inlet module on the bottom cone. Lock it with the locking ring.
3. Mount the module ring on the inlet module. Lock it with the locking ring.
4. Mount the filter plate on the module ring. Lock it with the locking ring.
5. Mount 1 st filter. Locked them with 1 filter-locking ring(s).
6. Mount the filter cleaning unit (tank) on the filter plate. Then lock with star knob.
7. Mount the outlet module on the filter plate. Lock it with the locking ring. Route cable through bulkhead bushing. Connect
compressed air hose.
8. Install the cover on the outlet module. Lock it with the locking ring.
After mounting the filter cyclone, the following must be done:
1. Connect inlet and outlet.
2. Connect the filter cleaning to compressed air and control voltage from the control cabinet. For values in detail see Technical
data.

Trial run

Make sure that the vacuum generator is correctly installed and that the inlet and outlet are connected to the piping system. The
piping system between the filter cyclone and the vacuum generator must be free of particles. Check the grounding of the piping
system between the units in the system.
Verify that the output device is securely fastened so that no air is sucked in that way and that the barrel is properly grounded.
12
S11000, Art no. 99051-A