IMPORTANT INSTALLATION INSTRUCTIONS (Continued)
3. Wrap a 3" (7.62 cm)
long piece of PTFE
tape to the right
around the male
threads of the fittings.
Wrap tightly so that
it conforms to the
threads of the fitting
and overlaps about
1/2". (Figure 3)
Figure 3
Compression
Fittings
4. Screw one fitting into
the filter outlet (top)
and the other fitting
into the filter inlet
(side). Tighten both
fittings with a wrench.
Do not overtighten.
(Figure 4)
Figure 4
5. Measure down from
the centerline of the
Cold Water Line
filter inlet about 3" and
marke the tube. From
this mark, measure
up 8" and mark the
tube. This is the sec-
tion of the tube to be
removed. If neces-
sary, because of tight
Shut Off
Valve
quarters, additional
tube can be cut away.
(Figure 5)
Figure 5
6. Cut the cold water
tube. Place a pan
under tube to catch
any water that may be
present. (Figure 6)
NOTICE
• Install on COLD
water lines only.
Figure 6
7. Two compression
fittings are required
Nut
for the tube ends.
Ferrule
Check the tube size.
Use 5/8" x 3/8", 3/8"
Compression Fittings
x 3/8" or 1/2" x 3/8"
compression fittings
as required. Slip nut
and ferrule on water
Ferrule
tubing as shown and
Nut
fasten fittings in place.
Figure 7
(Figure 7)
8. Cut two lengths of
3/8" soft copper
tubing and bend to
shape as shown.
Bend tubing to form
gentle curves rather
than sharp bends.
(Figure 8)
IMPORTANT NOTE
Do not crimp copper
tubing.
9. Connect both pieces
of tubing to filter and
water tube as shown
with compression
fittings. Do not over-
tighten nuts.
(Figure 9)
10. Remove housing by
grasping with both
hands and turning
to the left. A wrench
may be used on the
square lug at the bot-
tom of the housing if
necessary.
(Figure 10)
11. Install cartridge by
threading into head
about 5-6 revolutions.
Do not overtighten.
Cold Water Line
Lubricate o-ring with
Section of Tubing
water and put it back
Removed
in housing groove.
Thread the housing
back on the head and
hand tighten. Using of
wrench to tighten the
housing may damage
housing and result in
water leakage.
(Figure 11)
12.Open the cold water faucet to expel any trapped air. Open
the shut-off valve to allow water to enter the filter. If any
leaks occur, close the shut-off valve and open the faucet
to relieve the pressure, then gently tighten the fitting that
is leaking. Flush 10 gallons through system before use
(approximately 5 to 7.5 minutes).
5
Tubing
Figure 8
Outlet
Completed Connections
Inlet
Figure 9
Figure 10
O-Ring
Cartridge
Figure 11