SOMFY S&SO-RS100 io HYBRID Instrucciones página 57

Ocultar thumbs Ver también para S&SO-RS100 io HYBRID:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
S&SO-RS100 io Hybrid
Operate the roller shutter and allow it to stop
3)
automatically at the upper end limit (if stops) or lower
end limit (if rigid links).
Press once on
4)
and forth movement by the roller shutter:
The setting for the first end limit is confirmed.
Move the roller shutter to the desired lower end limit
5)
(no rigid links) or upper limit (no stops).
Press once on
6)
two back and forth movements by the roller shutter:
The setting for the end limits is confirmed and the drive exits set mode.
The procedure for modifying the end limit settings is identical to the initial setting procedure.
To modify the settings at a later time, repeat step A1 
Step A2 (optional): Programming a io-homecontrol
This guide describes the programming of a Somfy Smoove io type io-homecontrol
point.
Position the roller shutter at its half-way position.
1)
On the wired control point, press three times on
2)
 and press once on
forth movement of the roller shutter:
The radio is activated and the drive is in
programming mode.
The drive is in programming mode for ≈ 10 min.
Briefly press the PROG button on the Somfy
3)
io-homecontrol
®
programme:
The roller shutter moves back and forth:
the control point has been programmed in the drive.
Some control points have an ON/OFF button. To activate them, press the ON/OFF button at
the back of the control point.
The rotation direction of the drive self-adjusts automatically during the first few cycles.
During the first few movements, the  
without the need for any settings, after maximum 2 complete cycles, from stop to stop).
For a roller shutter less than 0.5 m² (0.6 m x 0.7 m), see chapter Questions on S&SO-RS100
io HYBRID?
Copyright© 2014-2017 SOMFY ACTIVITES SA, Public Limited Company. All rights reserved.
and press on
until there is back
and press on
until there is back and
local control point you want to
3)
5)
until there are
b
.
control point
®
1)
3)
Λ/V
orders may be inverted (they adjust automatically
4)
x 1
2.5 s
6)
x 1
2.5 s
2)
1 2
4 3
x 3
2.5 s
PROG. 0.5 s
EN
x 2
control
®
55
Tabla de contenido
loading

Tabla de contenido