Before Each Use; After Each Use - Legend Brands VersaCarpet VC700 Manual De Uso

Limpiadora de alfombras y tapicería
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

MAINTENANCE
WARNING! ELECTRIC SHOCK HAZARD. Unplug unit before cleaning or servicing.
Important: Do not tip unit on its back, or gearcase oil may leak out. If an oil leak occurs, clean up any oil with a
soft cloth and check gearcase oil and top off as necessary. See "Check gearcase oil levels," below.

Before each use

After each use

Monthly
As needed
Every 50 hours
of use
Every 500 hours
of use
49-090B VC700-115V 2014-05
All manuals and user guides at all-guides.com
Inspect the electrical cord for damage. Look for fraying, cuts, etc. Replace the cord if you
find any damage. Use replacement part no. 30-099.
Inspect hoses, water lines and seals. Replace as needed.
Inspect vacuum shoes and gasket. Replace shoe and gasket when grooves in shoe are no
longer visible or when shoe is excessively scratched or gouged.
Flush out tank and rinse basket clean. Disconnect solution feed tubes and remove bottles.
Attach a vacuum hose to the accessory port, place the other end in a bucket of clean water
and extract until pumpout hose discharge runs clear. Be sure to orient basket with hole facing
the pipe opening when replacing.
Inspect and clean in-tank filters. Remove from tank and rinse clean. Wipe out tank interior
with damp cloth and reinstall filters. Be sure to orient bottom tank filter horizontally and ensure
that it is firmly in place.
Rinse off extraction head and accessory tools with clear water.
Lift off solution inlet cover and rinse clean. Remove any debris from stem and cover and
wipe clean. After cleaning, reinsert carefully, ensuring stem is properly seated and the cover is
pressed down tightly.
Flush out solution lines. Remove solution feed tubes from bottles and place ends in a cup of
plain warm water. Switch unit on and operate solution control lever and prespray wand until
lines are flushed.
Wipe off feet and rotary head with a damp cloth.
Inspect tank cover seal for tears or rips. Replace if needed.
To maintain appearance, wipe interior and exterior surfaces with a damp cloth. For deep
cleaning and a lasting, protective shine, use an automotive interior cleaner.
Check gearcase oil levels. Remove vented gearcase plug. While looking into vent plug hole,
tilt unit back to allow the rotary head to be turned. Turn the head until the vent plug hole is
visibly aligned with the hole in the gear web. Now place the unit flat of the floor or table and
insert a screwdriver or similar tool to gauge the oil level. If the oil level is less than 1/8 inch,
add Sapphire Scientific gear oil (part number 13-053). Do not overfill. Reinstall vent plug when
finished.
WARNING: If a high-pitch vacuum motor sound is heard, TURN UNIT OFF IMMEDIATELY.
Use the manual pumpout feature to empty the tank, remove the cover and inspect all three
filters. Clean as necessary.
If poor pumpout performance is observed (i.e., waste tank fills quickly) or if the vacuum mo-
tor shut-off is triggered frequently (signaled by a high-pitch vacuum mo-tor sound), inspect
pumpout impeller and in tank filter. Rinse filter to clear out debris accumulation. If impeller is
pitted, cracked or bent, replace impeller and gasket.
If excessive consumption of Step 2/3 chemical observed, disassemble and clean inline
filters, valves and orifices.
NOTE: More frequent cleaning and/or replacement may be required in hard water areas.
If blower makes excessive noise, bearings or brushes may be worn out.
Clean pump check valve and basin.
Inspect vacuum blower motor brushes. Replace if needed.
VISIT WWW.VERSACLEANSYSTEMS.COM
7
Legend Brands, Inc.
Tabla de contenido
loading

Productos relacionados para Legend Brands VersaCarpet VC700

Este manual también es adecuado para:

67-040

Tabla de contenido