065612 Secure-Tec Automatic_065612 Secure-Tec Automatic 1 1
Operating Instructions
Technical data
Designation:
Supply voltage:
Total output:
Switching threshold range:
SPD:
Highest continuous voltage U
Combined surge U
Combined surge U
Protection level Up (L-N):
Protection level Up (L-/N-PE): 2.2 kV
Connecting line:
Functionality and Operation
Main switch
With the two-pole, illuminated main switch the
extension socket can be switched off completely.
Surge protection
The built in surge voltage suppressor prevents
appliances connected to the multiple socket outlet
from being damaged by voltage peaks in the
mains, e.g. as a result of indirect lightning strikes
or the activation of inductive loads, such as
motors, heaters, lamps, etc. For a correct
operation, the multiple socket must be connected
14
Multiple socket
Model ST BMP 0819 V2
Model ST BM 0619 V2
230 V~ / 50 Hz
max. 16 A / 3500 W
approx. 8 W – 80 W
Type 3
: 250 V~ / 50 Hz
C
(L-N):
10 kV
OC
(L/N-PE): 10 kV
OC
1.8 kV
3 m H05VV-F
3G x 1.5 mm
Secure-Tec
2