Technical data LOGO! 12/24 RCE Basic (continued)
Digital outputs
Number
Type of outputs
Electrical isolation
In groups of
Control of a digital output
Output voltage
Continuous current I
(per terminal)
th
Incandescent lamp load (25,000 switching cycles) at
Florescent tubes with ballast
(25,000 switching cycles)
Conventional florescent tubes, compensated
(25,000 switching cycles)
Florescent tubes, uncompensated (25,000 switching cycles)
Derating
Short-circuit proof, cos 1
Short-circuit proof, cos 0.5 – 0.7
Parallel connected outputs for increased power
Fusing of an output relay (if desired)
Switching frequency
Mechanical
Ohmic load / lamp load
Inductive load
Subject to change without notice
Please refer to the LOGO! 8 manual for further information.
© Festo Didactic 8086581
4
Relay outputs
Yes
1
Yes
24 V DC
Maximum 10 A per relay
1000 W
10 x 58 W
1 x 58 W
10 x 58 W
None; within overall temperature range
Power protection B16, 600 A
Power protection B16, 900 A
Not permissible
Maximum 16 A, characteristic B16
10 Hz
2 Hz
0.5 Hz
®
LOGO! 8 TP EduTrainer
– Operating instructions
29