5.5
Starting the tool
•
Operate the on/off switch to activate the tool. The green LED will light and the electric motor runs at
slow speed.
•
The tool operates if the deadman's handle is turned to position
NOTICE
If the tool is not used, it will switch off after a while. The green LED will blink. Press the on/off
switch 2 times to re-activate the tool.
NOTICE
When the tool is not used for 10 minutes the battery pack will switch off. The green LED will
not light anymore. To activate the battery pack again:
•
Press the SOC indicator button, or
•
Operate the on/off switch again, or
•
Reinstall the battery pack.
5.6
Operate the deadman's handle
The deadman's handle is used to determine the movement of the plunger(s). In the neutral position no
pressure is built up and the oil flows back to the pump without pressure. If the deadman's handle is
released, it returns automatically to the neutral position and stops the movement of the plunger(s).
/i
Hold the deadman's handle in this position to open the tool/blades. Pressure is built
up in the tool. Return oil from the tool flows back to the pump without pressure.
Hold the deadman's handle in this position to close the tool/blades. Pressure is built
up in the tool. Return oil from the tool flows back to the pump without pressure.
6
Use
6.1
General
The equipment of a rescue system must always be ready for use. That means the equipment must be
checked and inspected directly after use, before it is put away.
WARNING
Make sure you are up to date on all safety regulations and that you have mastered the use of
all equipment of the system you are going to work with.
6.2
Before use
•
Before use, always check the State Of Charge of the battery pack. See section 3.6.
BCU * A *
All manuals and user guides at all-guides.com
916.400.018_003
or
.
EN