SOLUTION OF THE PROBLEMS
Problem
Water doesn't come out of
the tap
The water supply doesn't
close
The water flow has been
diminished
Indication
The sensor flashes
continuously when the
hands of the user are within
the action range
The sensor doesn't flash
when the hands of the user
are within the action range
The sensor flashes when the
hands of the user are within
the action range
The sensor flashes when the
hands of the user are within
the action range
The sensor also flashes
when the action range is
free
The sensor doesn't flash
when the hands of the user
are within the action range
Cause
Low battery load level
Unsuitable action range
Run up battery load level
The sensor is dirty or is
hidden
The sensor receives
reflections from a mirror or
another object
Debris, scaling or damages
in the solenoid valve
The feeding pressure is
higher than 5 bar
Damaged electronic part
Debris, scaling or damages
in the solenoid valve
The sensor receives
reflections from a mirror or
another object.
The sensor is dirty or is
hidden
The sensor receives
reflections from a mirror or
another object
Damaged electronic part
The aerator or the feeding
filters are dirty or stopped
11
Solution
Replace the battery
Adjust the sensor sensitivity
Replace the battery
Clean or remove possible
interferences
Remove the cause of the
reflection
Disassemble the solenoid
valve, check the running
and clean or replace
eventually
Reduce the feeding pressure
Replace the electronic part
Disassemble the solenoid
valve, check the running
and clean or replace
eventually.
Remove the cause of the
reflection
Clean or remove possible
interferences
Remove the cause of the
reflection
Replace the electronic part
Check, clean and replace
eventually
Tabla de contenido