Installing Lp Gas Tank; Operating Instructions - Fire Island GAD1447M Manual De Usuario

Tabla de contenido
Need help? 1.888.398.8643
8
Do not return to place of purchase.

Installing LP Gas Tank

To operate, you will need one precision-filled standard grill LP gas
tank with external valve threads .
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving this
outdoor fire pit.
Inserting LP Gas Tank
W WARNING: Make sure LP gas tank valve is closed.
1 .
Open door .
2 .
Make sure the control knob is in the " OFF" position (Figure 3) .
3 .
Loosen LP gas tank retainer bolt by turning counter-clockwise .
4 .
Place precision-filled LP gas tank upright into hole in outdoor fire pit base so the tank valve
is facing the gas line connection .
5 .
Secure tank by turning LP gas tank retainer bolt clockwise until tight .
6 .
Close door .
Connecting LP Gas Tank
1 .
Make sure the control knob is in the " OFF" position
(Figure 3) .
2 .
Before connecting, be sure there is no debris caught in the
head of the LP gas tank, head of the regulator valve or in the
head of the burner or burner ports .
3 .
Connect regulator/hose assembly to tank by turning knob
clockwise until it stops .
4 .
Perform leak check per "Checking for Leaks" section .
Disconnecting LP Gas Tank
1 .
Make sure the control knob is in the " OFF" position
(Figure 3) .
2 .
Before disconnecting, make sure the LP gas tank valve is
"CLOSED ."
3 .
Disconnect regulator/hose assembly from LP gas tank by
turning knob counterclockwise until it is loose .
W CAUTION: LP gas tank must be properly
disconnected and removed prior to moving
this fire pit.
4 .
Place the protective cap cover on the LP tank and store the tank outdoors in a well
ventilated area out of direct sunlight .

Operating Instructions

Checking for Leaks
W WARNING: Before using this outdoor
20 lb
fire pit, make sure you have read,
9 Kg
understand and are following
all information provided in the
"Important Safeguards" section
12.2 in. / 31 cm
on page 2. Failure to follow those
instructions can cause death, serious
injury or property damage.
W
W WARNING: The burner must be
replaced prior to the appliance being
put into operation if it is evident
that the burner is damaged. The
replacement burner shall be that
specified by the manufacturer.
Burner Connections
1 .
Make sure the regulator hose and valve
connections are securely fastened to the burner
and the tank .
2 .
Visually check the connection between the
burner/venturi tube and orifice .
3 .
Make sure the burner/venturi tube fits over the
orifice .
W WARNING: Failure to inspect
this connection or follow these
instructions could cause a fire or an
explosion which can cause death,
serious bodily injury or damage to
property.
4 .
Please refer to diagram for proper installation
(Figures 1 and 2) .
5 .
If the burner/venturi tube does not rest flush
to the orifice, as shown, please contact
1 .888 .398 .8643 for assistance .
Tank/Gas Line Connection
1 .
Make 2-3 oz . of leak detection solution by
mixing one part liquid dishwashing soap with
three parts water .
2 .
Make sure control knob is in the " OFF"
position (Figure 3) .
3 .
Connect LP gas tank per "Installing LP Gas
Tank" section .
4 .
Turn LP gas tank valve to "OPEN ."
5 .
Spoon several drops of solution, or use a squirt
bottle, at all "X" locations (Figures 1 and 2) .
a . If any bubbles appear, turn LP gas tank valve
to "CLOSED," reconnect and re-test .
b . If you continue to see bubbles after
several attempts, turn LP gas tank valve to
"CLOSED" and disconnect LP gas tank, per
"Disconnecting LP Gas Tank" section . Contact
1 .800 .762 .1142 for assistance .
c . If no bubbles appear after one minute, turn
LP gas tank valve to "CLOSED," wipe away
solution and proceed .
Lighting
W DANGER: Failure to follow these
lighting instructions may result in
serious bodily injury or death, or in a fire or an explosion causing
damage to property.
W WARNING: NEVER light the burner with the cover on the outdoor fire
pit.
W CAUTION: Keep outdoor gas appliance area clear and free from
combustible materials, gasoline and other flammable vapors and
liquids.
W CAUTION: Do NOT obstruct the flow of combustion and ventilation air.
W CAUTION: Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
1 .
Make sure all labels, packaging and protective films have been removed from the outdoor
fire pit .
2 .
Check for obstructions of airflow to the burner . Spiders, insects and webs can clog the
burner/venturi tube . A clogged burner tube can lead to a fire .
3 .
Make sure control knob is in the " OFF" position (Figure 3) .
4 .
Clear small area of lava rocks/fire glass away from the igniter cover (Figure 4) .
Replacement Parts
1.888.398.8643
Figure 1
LP Gas
Connection
Figure 2
X
X
X
Figure 3
OFF / ARRÊT
Figure 4
Figure 5
LP Gas Valve
with Orifice
X
X
15.75 in - 23.6 in
40 – 60 cm
Tabla de contenido
loading

Tabla de contenido