WOLF SW MV: CONTROL BOARD FOR SWING GATES
NOTE: WHEN CONNECTING AERIAL ANTENNA, MAKE IT ALWAYS WITHOUT CURRENT.
ATTENTION:
Safety devices:
• Option 1 (connect 11 and 14): door stops and closes.
• Option 2 (connect 12 and 14): door stops and opens.
• Option 3 (connect 13 and 14): door stops.
AMPERE-STOP (RED)
POWER (BLUE)
Engine power regulation. Rotate to the LEFT to decrease it and rotate to the RIGHT to
increase it.
SOT STOP (WHITE)
Soft stop motor regulation. Only with Option 7 ON. Rotate to the LEFT to decrease it and
rotate to the RIGHT to inc rease it. Available for opening and closing.
AUTOMATIC CLOSING TIME (GREEN)
Regulates the stand-by time before the automatic closure. Turn to the LEFT to decrease it and to the
RIGHT to increase it.
Minimum 3 seconds.
Maximum 120 seconds.
1 AUTOMATIC CLOSURE
ON: Activated. Door closes automatically.
OFF: Deactivated. Door does not close automatically.
2 COMUNITY/CLOSE BY PHOTOCELL
ON Inhibitor of the transmitter or START during opening. During closing, activating the START or
the transmitter reverses the maneuver. THE DOOR CLOSES THE AUTOMATIC CLOSING TIME HAS
PASSED OR ONCE 5 SECONDS AFTER CUTTING THE PHOTOCELL.
Dip 1 must be activated for this option to work.
OFF START switch (1-2) and transmitter, door work normal, step by step.
3
DISABLED
REGULATIONS
OPTIONS
14