INSTALLATION OF ELECTRODE MACHINE
All welding parameter controls are placed on the welding machine front panel.
Plug the power cord into a 230V single phase mains socket, making sure that it is earthed.
Ref. 1
Switch-on for the inverter ignition.
Ref. 2
"ON" LED indicator.
Ref. 3
LED indicating inverter blockage due to overheating.
Ref. 4
Power knob for welding current output.
Electrodes 1,60 mm (1/16"): minimum current 30A maximum current 50A
Electrodes 2,00 mm (5/64"): minimum current 40A maximum current 70A
Electrodes 2,50 mm (3/32"): minimum current 70A maximum current 110A
Electrodes 3,25 mm (1/8"): minimum current 110A maximum current 140A
Electrodes 4,00 mm (5/32"): minimum current 140A maximum current 180A
Ref. 5 Ref. 6 Connect positive (+) and negative (-) connectors to the earth cable and the electrode holder.
Rutile electrodes need the electrode holder be connected to negative pole (-) while basic electrodes need the
electrode holder connected to positive pole (+). In any case, for each type of electrode consult the instructions
printed on the electrode box.
The HOT START function is automatic.
Insert the un-coated end of the electrode into the holder. Connect the earth terminal to the weld piece. Scratch the
electrode on the piece. To end welding, move the electrode away and the arc will extinguish.