5 DIAGNOSTICS AND SOLUTIONS
The repair or replacement of any parts in the
system must be carried out only by qualified
engineers.
The repair or replacement of any parts in the system by
personnel other than authorised personnel shall cause the
product warranty to become null and void.
The system must not be modified in any way.
The manufacturer declines any responsibility should the
operator not follow these instructions.
Incorrect power supply
Cause
Faulty potentiometer/encoder for the adjustment
of the welding/cutting current.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sys-
tem repaired.
Cause
Faulty electronics.
Solution
Contact the nearest service centre to have the sys-
tem repaired.

6 TECHNICAL SPECIFICATIONS

Power supply voltage
Maximum input power (W)
Input current
Dimensions (lxdxh)
Weight
Power supply cable
Manufacturing Standards
10
RC 18
15V
0.2W
15mA
160x160x50 mm
0,7 Kg.
6 m
EN 60974-1/ EN 60974-10
RC 180
15V
0.2W
15mA
160x160x50 mm
0,7 Kg.
6 m
EN 60974-1/ EN 60974-10