No air intake
Is the filter clogged?
Loud noise
Is the unit placed on a horizontal
when running
and flat surface?
Is the filter clogged?
E2
Humidity sensor problem
LO
Environmental humidity
is below 20%
HI
Environmental humidity
is above 90%
CL
Low temperature protection, the
environmental temperature <5°C
CH
High temperature protection,
the environmental temperature
>35°C
8. DECOMMISSIONING
8.1
STORAGE
Long-term storage – If you will not be using the unit for an extended period of time (more
than a few weeks) it is best to clean the unit and dry it out completely. Please store the unit
per the following steps:
a)
Press power button to switch off and unplug the unit.
b)
Drain the remaining water from the unit.
c)
Clean the filter and let the filter dry completely in a shaded area.
d)
Collect the power cord at the water tank.
e)
Re-install the filter at its position.
f)
The unit must be kept in upright position when in storage.
g)
Preserving the machine in ventilating, dry, non- corrosive gas and safe place indoor.
ATTENTION: The evaporator inside the machine has to be dried out before the unit is
packed to avoid component damage and molds. Unplug the unit and place it in a dry open
area for days to dry it out. Another way to dry the unit is to set the humidity point more
than 5% higher than the ambient humidity to force the fan to dry the evaporator for a
couple of hours.
8.2
DISPOSAL
WARNING!!! Releasing refrigerant into atmosphere is strictly forbidden!
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities. Contact your local government for information
regarding the collection systems available. If electrical appliances are disposed
of in landfills or dumps, hazardous substances can leak into the groundwater and get into
the food chain, damaging your health and well-being.
Wash the filter
Place the unit correctly
Wash the filter
Change a sensor
The dehumidifier shuts down
for self-protection
17