en
| 26 | BEA 055 | Technical data
7.
Technical data
7.1
Exhaust gas measurement
Component
Measuring range
CO
0.000. 10.00 % by vol
CO
0.00. 18.00 % by vol
2
HC
0. 9999 ppm by vol
O
0.00. 22.00 % by vol
2
Lambda
0.500. 9.999
CO
0.00. 10.00 % by vol
vrai
(not in Germany)
NO
0. 5000 ppm by vol
Accuracy class 1 and class 0 as per OIML R99 Ed. 2008
7.2
Power supply
Property
Input voltage (DC)
Power (P)
7.3
Temperature measurement/engine
speed measurement
Temperature
Oil temperature probe
Engine speed (gasoline)
BEA 040/BDM 300
*)
Engine speed (diesel)
BEA 040/BDM 300
*)
Special accessories
*)
|
1 689 989 111
2020-09-24
7.4
Property
Dimensions W x H x D:
Resolution
Weight (without accessories)
0.001 % by vol
0.01 % by vol
1 ppm by vol
7.5
0.01 % by vol
0.001
0.01 % by vol
Property
Operation
1 ppm by vol
Storage and transport
Atmospheric pressure
Value/range
7.5.1
11 V – 16 V
Property
20 W
Storage and transport
Operation (at 25°C and 24 h)
Measurement accuracy
Min.
Max.
7.5.2
-20°C
150°C
Property
Min.
Max.
Storage and transport
Operation
400 min-1
8000 min-1
Measurement accuracy
Min.
Max.
7.6
400 min-1
6000 min-1
Class
Mechanical
Electromagnetic
7.7
Property
Workplace emission sound pressure
level as per EN ISO 11204
Sound power level as per
DIN EN ISO 3744
Dimensions and weights
Temperature/atmospheric pressure
limits
Air pressure
Air humidity
Device class (MID)
Noise emissions
Value/range
370 x 190 x 230 mm
14.6 x 7.5 x 9.1 inch
5,2 kg
11.5 lb
Value/range
5 °C – 40 °C
41 °F – 104 °F
-25 °C – 60 °C
-13 °F – 140 °F
700 hPa − 1060 hPa
Value/range
700 hPa – 1060 hPa
700 hPa – 1060 hPa
700 hPa – 1060 hPa
Value/range
<75 %
<90 %
<90 %
Level
M1
E2
Value/range
< 70 dB(A)
< 72 dB(A)
Robert Bosch GmbH