All manuals and user guides at all-guides.com
PRESSURE SWITCH -
REPLACEMENT
Risk of Bursting.
Pressure loads
beyond design limits may cause
tank rupture or explosion. Pressure
switch operation is related to motor
HP, tank rating, and safety valve
setting. Do not attempt to adjust,
remove, or defeat the pressure
switch, or change and modify any
pressure control related device. If
replacement is necessary the same
rated switch must be used. Contact
a trained service technician for
replacement.
TO REPLACE REGULATOR
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug air compressor.
3.
Remove the regulator ring and
remove the console cover.
Regulator
Ring
4.
Using an adjustable wrench loos-
en pressure relief tube nut at air
tank and pressure switch.
5.
Lift retaining clip from handle and
remove handle.
Retaining clip
1000003598
6.
Regulator
7.
8.
9.
10. Assemble the regulator and orient
Cover
NOTE: Arrow indicates flow of air.
Make sure it is pointing in the direction
of air flow.
11. Reapply pipe sealant to outlet
12. Reassemble outlet pressure
13. Rotate pressure switch assembly
14. Replace console cover and regu-
Handle
15. Replace handle. Refer to "Handle
22- ENG
Using an adjustable wrench, rotate
the pressure switch assembly as
shown.
Outlet
Pressure
Gauge
Remove the outlet pressure
gauge, tank pressure gauge, and
quick connect (if equipped) from
the regulator.
Remove the regulator.
Apply pipe sealant tape to the
nipple.
as shown in previous figure.
Regulator
Arrow
pressure gauge, tank pressure
gauge, and quick connect.
gauge,tank pressure gauge, and
quick connect. Orient outlet pres-
sure gauge and tank pressure
gauge to read correctly. Tighten
quick connect with wrench.
into correct position.
lator ring.
Assembly" paragraph in the
Assembly section.
Tank
Pressure
Gauge
Quick
Connect