1.4 Connection
Install a thermal-magnetic switch with RCCB (not supplied) on the wall. The
•
wall-mounted main switch must be 2-pole with adjustable RCCB and adjustable
sensitivity I∆n.
Before to connection to the power, check that the voltage and frequency values
•
displayed on the technical plate are compatibles with the values of the power
supply.
The appliance is supply for a connection with values indicated on technical plate
•
(See pag. 15/48 for an example) and those values must be respected to allow the
correct use of the appliance.
Before doing any work, cut off the main electricity supply, connect the
•
appliance to a normalize plug available the operating voltage.
Connect the cable to an adequate electric socket. The appliance must be
•
connected to earth in accordance with current standard.
The earth wire must be longer than the others so that if the cable blocker should
•
break, it will disconnect after the tension wires.
At full working, the applied voltage must do not overreach the rated voltage
•
±10%.
The appliance must be connected to an equipotential system and the
•
effectiveness of this one is to check, according to normative in force. The
connection screw is identified by the
The cut-out switch or the plug must be near the appliance and easily to reach.
•
symbol.