BGS technic BGS 8853 Manual Del Usuario página 7

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

RECOMMENDED COMPRESSED AIR SYSTEM
No.
1
Air tool
2
Air hose
3
Quick coupling
Oiler
4
(for tools with motor)
5
Pressure reducer
MAINTENANCE
• Air tools should be operated on air systems that have an automatic oiler.
When using air systems that do not have an automatic oiler, air tools
must be regularly added oil to the air tool via the air connection.
• Before first use, add 4 to 5 drops of air device oil to the air connection of
the device.
• Do not use engine or gear oil to oil pneumatic tools; only use oil for
pneumatic tools.
• Drain the compressed air system before each use. Water in the air lines
leads to a loss of performance and damage to the air tool.
• Clean or replace the air filter on the compressor at the prescribed
intervals.
• Only operate the air tool with the maximum pressure specified in the
chapter "Technical data".
UNPACKING
When unpacking, make sure that all parts are present.
Contact your dealer if parts are missing or damaged.
SAFETY WHILE OPERATING
Take enough time for a careful selection of a working area. Take care that your workplace is near to
the compressor and blasting material. Attention! Always stay aware. Remove the device or other
objects from the working area. Persons and animals must not remain in the working area. Never
direct the air tool against persons or animals. Always wear safety equipment like safety glasses and
dust masks when working with this air tool (see chapter "Occupational Safety").
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Designation
Tel.: 02196 720480
Fax.: 02196 7204820
No.
Designation
6
Drainage/filtering unit
7
Drainage valve
8
Shut-off valve
9
Dryer/filter unit
10
Compressor
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed
Tabla de contenido
loading

Tabla de contenido