prevent scratches.
5. Pay attention to the correct position of the sealing rings (G) and the flat O-ring (I) when replacing
the quartz glass in the housing. Never use force!
6. Carefully replace the lamp in the quartz glass. Screw the screw ring (E) onto the housing again.
There is only one way to fit the lamp into the quartz glass!
7. Connect the end of the cable (D) to the top of the lamp (A).
Technical specifications
UV-C PL-S module TUV
Voltage
UV-C (%) after 6,000 hours
Max. Flow
Max. pressure
Ø Inlet/outlet
Type of UV-C system
Article number: BE21122 Blue Lagoon UV-C 10,000 l/12 Watt (230V; 50Hz)
Article number: BE21121 Blue Lagoon UV-C 10,000 l/15 Watt (120V; 60Hz)
Replacement lamps
Article number: B212012 UV-C PL-S module 12W (230V; 50Hz)
Article number: B212012USA UV-C PL-S module 15W (120V; 60Hz)
Replacement cable
Article number: E801205 cable for the Blue Lagoon Tech Spa UV-C 12W 230V
Article number: E801219 cable for the Blue Lagoon Tech Spa UV-C 15W 120V
For the safety instructions and terms of guarantee we would like to
refer to the general UV-C manual from VGE International B.V.
UV-C 12W
UV-C 15W
12 Watt
15 Watt
230 V
120 V
85%
85%
3,000 l/h
4,000 l/h
1 bar
1 bar
63mm/50mm/1,5"
2"/1,5"