BLUE LAGOON TECH SPA UV-C 12 & 15 WAT T
OPERATION
EN
The special Philips UV-C lamp in the Blue Lagoon Tech Spa UV-C generates UV-C radiation with
a wavelength of 253.7 nm, and this ensures the destruction of bacteria, moulds and viruses. This
lamp has been specially designed by Philips, and is ideal for water temperatures up to 40 degrees
Celsius. The Blue Lagoon Tech Spa UV-C ensures fresh, clean and clear water in an efficient and
environmentally-friendly manner. The water is guided through the UV-C device by means of a
pump. The UV-C radiation neutralises bacteria, viruses and other primitive organisms and prevents
their reproduction. The Blue Lagoon Tech Spa UV-C has an integrated electronic ballast. This ballast
ensures maximum lamp performances. In addition, the stainless steel interior provides additional
reflection of the UV-C radiation, thereby increasing the efficiency up to 35%. Thanks to the Blue
Lagoon Tech Spa UV-C, your water will be disinfected efficiently and safely, and the quality of your
water will remain excellent. Contains connecting pieces. The device can be connected using PVC
tube or hose.
INSTALLATION OF THE UV-C DEVICE (DRAWING 1)
The ideal place for the installation of the device is immediately behind the filter. Never submerge
this device in water. Always install the device outside of the pool. Ensure that there is always water
flowing through the unit if the lamp is on.
1. Determine where the device will be installed. (always install vertically, see Drawing 3).
2. Fit the unit into the circuit using the three-part couplings (F).
3. Connect the end of the cable (D) to the top of the lamp (A).
4. Activate the pump and check the flow and any leakage of the system.
5. Insert the plug of the UV-C device into a wall socket with a safety ground and fitted with an residual
current circuit-breaker (max 30 mA). Check that the lamp is on by looking through the transparent
components of the device. The unit is switched off by pulling the plug out of the socket. The lamp
is already earthed. The housing has an additional means of earthing; see drawing 1, position H.
DISMANTLING/MAINTENANCE
Always switch off the power supply while maintaining/dismantling the device.
The device must be cleaned twice a year. If there is an increase in pollution, the quartz glass tube (B)
must be cleaned. The special lamp (A) must be replaced after 6,000 operating hours (± 1x a year) at
the latest. The stainless steel interior can be cleaned with a soft brush.
1. Unscrew the three-part couplings (F) and drain the water from the device.
2. Unscrew the screw ring (E), remove the lamp from the quartz glass and, if necessary, replace the
special lamp (A). As these parts are very fragile, caution is essential.
3. Carefully remove the quartz glass (B) using a large, flat screwdriver (see Drawing 2). Never use force!
4. Clean the quartz glass with a suitable agent. Always use a soft cloth to clean the glass and
4
| BLUE LAGOON UV-C TECH SPA 12 & 15 WATT
Please read carefully through these instructions
for use before installing this device.