Step 1: Before cleaning, always
disconnect the pump from the power
source and remove the inlet screen.
Step 2: Remove the impeller
housing to expose the impeller
assembly.
Step 3: Remove the
impeller assembly by gently
pulling on the impeller
blades. The impeller is held
in place by a magnet. NOTE:
This pump uses a very
strong magnet. To protect
your fingers from potential
injury, use caution when removing
or inserting the impeller.
Step 4: Use a soft cloth or brush
and warm water to clean the
impeller and the inside of the
impeller and rotor housing.
Step 5: Reassemble all pump
parts, place the pump inside the
pump barrier bag and place in
water before reconnecting to the
power source.
TROUBLESHOOTING
IF THE PUMP FAILS TO OPERATE:
• Check to make sure the power cord is plugged in, the
pump is getting power.
• Check the pump outlet and any tubing, nozzles, spitters
etc. for kinks or obstructions.
• Remove the inlet screen and/or pump cover, and impeller
housing to expose the impeller. Turn the impeller to ensure
that it is not broken or jammed. Also check to make sure
that the ceramic shaft or bearings are not broken.
IF THE PERFORMANCE OF THE PUMP IS NOT
SATISFACTORY OR THE PUMP DOES NOT FLOW EVENLY:
• Check to make sure the pump is completely submerged in
water.
• Check to make sure the impeller and the housing are
clean.
• Check to make sure the pump barrier bag is clean.