13
Final inspection / Inspección final / Inspeção final
Once installation has been completed, the following aspects in particular must be inspected:
a)
Are the support ropes and the lateral rope connected to the correct anchors?
b)
Are the rope guides at the top and bottom of the posts installed correctly?
c)
Have the correct number of loops been left free on the left and right of the posts?
d)
Is the mesh correctly fastened to the support ropes?
e)
Have the correct number of wire rope clips been attached to the ends of the rope?
f)
Are the wire rope clips installed correctly?
g)
Has the correct torque been applied to the wire rope clips?
h)
Are the meshes connected correctly?
i)
Are the end meshes correctly fastened to the vertical ropes?
j)
Is the sag of the top support rope less than 3% of the distance between the posts?
Please consider the maintenance manual.
© Geobrugg AG, Switzerland
43/48
GBE 500A-R