To assign a Device ID of hex 07, leave the MSB switch on 0 and turn the LSB switch to 7. Device ID
switches should be set using a 0.1 inch (2.5mm) to 0.12 inch (3.0mm) flat blade screwdriver.
Changes made to the Device ID while connected to the network require a power cycle of the device in order to take effect.
Control Outputs
The Control Outputs, labeled 1 through 4, are isolated, voltage-free, software-configurable relay outputs.
The individual pins are labeled as follows:
1. (C): the common/ground pin
2. (NC): normally closed (connected to C when relay is not energized)
3. (NO): normally open (connected to C when relay is energized)

Control Inputs

The Control Inputs are labeled as follows:
1. (Ground symbol): logic common/ground input pin
2. (1–4): individual logic inputs
3. (10V): 10V reference voltage (when used as a switch input, a switch must be connected
between the input and logic common terminal)

Audio Outputs

Four plug-in barrier strip connectors provide analog audio signal output. The Vocia software enables a
nominal output level of +4 dBu, 0 dBu, or -10 dBu to support a wide range of connection devices. All plug-
in barrier strip connectors should be wired from left to right as follows:
1. High
2. Low
3. Ground