4.6 Size of the electrical cables
Always use cables of a suitable cross-section. The minimum cross-sections are listed
in the table below:
Cross-section in
mm²
2.5
4
6
10
5 Technical data (standard configurations)
Operating voltage: 12 or 24 VDC
Average consumption measured with internal temperature +5°C and outside
temperature 25°C. Average consumption is influenced considerably by the way the
refrigerator is used and the type of ventilation.
Refrigerant: R134a (the system's capacity is indicated on the refrigerator's data
plate).
The refrigerators meet the requirements of the EMC directive and bear the CE
marking.
Model
Free line 115 Elegance
(Static)
Free line 115 Elegance
(Ventilated)
50
Max 12 V cable length
AWG section
m/ft
13
11
9
7
Max. instantaneous
consumption
12/24Vdc (Amperes)
6.0/3.0
6.0/3.0
Max 24V cable length
m/ft
2.5/8
4/13
6/19
10/33
Max. instantaneous
consumption
12/24Vdc (Watt)
72
72
User Manual
5/16
8/26
12/39
20/66
Average
consumption at
25°C (Watt/24h)
363
257