that is specifi ed in the technical specifi cations
has been reached.
- Load the machine in such a way that the speed
does not decrease too much or the machine is
forced to stop.
- Always guide the fl exible power cable from the
tool to the rear. Never pull hard on the fl exible
power cable and never set it on or guide it over
any sharp edges.
- Only work in a safe and stable position.
- Take into account that there will be a reaction-
ary torsional momentum.
- Do not mix any solvents or solventcontaining
substances with a fl ash point of below 21 °C.
- Start up and run down the maschine un the
mixing container only.
- Do not reach into the mixing container with
your hands or insert any other objects into
while mixing is in progress.
- We recommend that you wear work gloves
and protective goggles when using the mixer.
Regulation require that you wear close-fi tting
clothing.
- Only for AS/NZS: The tool shall always be sup-
plied via residual current device with a rated
residual current of 30 mA or less.
5.3
Other safety risks
Even in cases where the machine is used correctly
and all relevant safety instructions have been ad-
hered to, the design engineering of the machine
and its operation mean that there may also be the
following safety risks:
- Danger that may be caused by the fl exible pow-
er cable.
- A concentration of dust which is harmful to
health when working in an area that is not suf-
fi ciently ventilated.
- Injuries caused by touching electrifi ed parts
when removing the machine or its parts if the
plugs on the fl exible power cable have not been
removed from the socket.
- You must only use original Festool spare parts.
5.4

Emission levels

Levels determined in accordance with EN 60 745
are typically:
Sound pressure level
Noise level
Uncertainty
The noise produced during work can damage
your hearing.
 Always use ear protection.
Vibration emission value a
directions) and uncertainty K measured in accord-
ance with EN 60 745:
Uncertainty
The specifi ed emissions values (vibration, noise)
– are used to compare machines.
– They are also used for making preliminary es-
– They represent the primary applications of the
Increase possible for other applications, with oth-
er insertion tools or if not maintained adequately.
Take note of idling and downtimes of machine!
6
Risk of accident if the machine is operated us-
ing unauthorised voltages or frequencies.
- The mains voltage and the frequency of the
- In North America, only Festool machines with
Risk of accident, electric shock
 Always pull the plug out of the socket before
6.1
Connecting and detaching the mains power cable,
L
= 86 dB (A)
see Fig. [2].
PA
L
= 97 dB (A)
WA
Switching On:
K = 3 dB
 Press the safety button [1-4].
 Press the on-off switch [1-5] and hold de-
 The on-off switch cannot be locked on.
8
CAUTION
timates regarding vibration and noise loads
during operation.
power tool.
Starting up and using the machine
WARNING
power source must correspond with the spec-
ifi cations on the machine's name plate.
the voltage specifi cations 120 V/60 Hz may be
used.
WARNING
performing any type of work on the machine.

Switching the machine on and off

Always hold the machine with both hands.
pressed.
(vector sum for three
h
a
= 5.5 m/s
h
K = 1.5 m/s
2
2
Tabla de contenido