CONNECTION
The Airzone hydronic production control board (AZX6CCPGAWI) controls the production unit of the installation. From this we
will receive the central mode of operation and the status of the request to each system connected, and to act on the production
team accordingly.
Nº
Power supply
NLT
Digital Inputs
Integration bus output
INT
DM1/DM2 Domotic bus outputs
Air to water domotic bus output
IU
Control relays
Systems search
SW1
Configuration
SW2
Power supply connector
This connector powers the main control board and all the elements connected to it.
Externally powered at 110/230 Vac. It is connected through a 3-pin terminal. Attach
the wires with the terminal screws following the color code. For added security, secure
the wires using the turret.
Deactivates the air conditioning through AC unit during DHW
DI4_ACS
production
DI5_HEAT
Sets the heating semiforced mode
DI6_COOL
Sets the cooling semiforced mode
DI7_STOP
Imposes the Stop mode in the system
AI1
Reserved for internal use
MODE_Y
Cooling mode
MODE_W
Heating mode
AIR_Y
Cooling air demand
RAD_Y
Cooling radiant demand
AIR_W
Heating air demand
RAD_W
Heating radiant demand
Description
ES
EN
FR
IT
PT
DE
15